The guidance below comes from our actual water-level station installations. Each point explains what we did, what we learned and what it means for your area.
Station readings must be verifiable against images
Our experienceIn 2026, we installed 20 DoRare Station units along rivers in 4 Thai provinces, with additional weather stations at 5 locations. Each cabinet has a camera that photographs a staff gauge for AI readings approximately every 15 minutes, plus a radar sensor for a separate water-level measurement.
What we learnedShowing the actual staff-gauge image beside its reading lets operators visually check that the displayed figure matches water conditions, and retain the image as supporting evidence.
What does it mean to you?Your stations should therefore have a way to cross-check readings from day one, such as a camera with a clear view of the staff gauge or an initial comparison with readings taken by staff.
Read the case study: 20 water-level stations across 4 provincesStations must also report their own condition
Our experienceIn the same project, every control cabinet runs on solar panels and batteries and sends data through a 4G router with a SIM card. The cabinet status page shows the battery, fan, router and SIM data usage, and operators can select from 4 power modes.
What we learnedField stations are remote and unattended. If the system cannot report a low battery or a lost connection, operators cannot tell whether missing readings are caused by water conditions or equipment. Power and communications planning is therefore part of the measurement system.
What does it mean to you?Before designing the system, we ask about mobile coverage and power sources at each location. Equipment alerts, such as an offline camera or low battery, are configured separately from water-level alerts.
See cabinet status monitoring in the 20-station water-level case studySet thresholds and alert recipients for each station
Our experienceIn the same project, operators can set 3 levels—normal, watch and critical—for each station. When the critical threshold is reached, the system sends a LINE or email alert as configured.
What we learnedEach location has its own staff gauge and camera position. Scale calibration and alert thresholds must therefore be configured per station, rather than using one setting for the entire system.
What does it mean to you?Before launch, prepare a list of the roles that should receive alerts at each level and station, including those responsible outside office hours.
See alert threshold settings in the 20-station water-level case study